DCX Transmitter: One of Our Legacy Products
DCX Transmitter
HPA Service Bulletins
180402 End of Production and Support for DCX Millenium, DCX/IOX, and DCX Paragon
170622 WEBGUI / ThalesView / TxView Support
140610 IOX/DCX Transmitter Maintenance Schedule (RevA 6-10-14)
130502 Stackpole Resistors in DCX/IOX HPAs (RevA 8-5-2013)
110611 DCX Focus Supply Current Sense Upgrade Procedure (RevA 1-6-12)
090701 IOX to DXC Transmitter Conversion Considerations (RevA 7-01-09)
070727 IOX/DCX Millennium Cabinet Interlock Diagram (RevA 7-27-07)
070302 Time & Date Change Procedure IOX/DCX (RevA 03-02-07)
061129 IOX/DCX Beam Control & CB3 Motor Operator Schematic (RevA 11-29-06)
041114 PLC Battery Replacement (RevA 4-5-05)
041014 Weekly DCX/Advantage Transmitter Log (RevA 10-13-04)
041012 Panel View Procedure: DCX Millennium & Paragon (RevA 10-12-04)
040831 Troubleshooting Crowbar Events (RevE 9-30-15)
040824 List of Recommended ATSC Test Equipment (RevB 7-05-06)
040706 Spellman Ion Power Supply Replacement (non-Millennium) (RevA1 9-12-05)
040704 HPA Controller Backplane Replacement (RevD 7-11-08)
040529 Emergency Tube Bypass: IOX/DCX (RevB 5-12-08)
040507 Millennium/Paragon Emergency PLC Bypass Procedure (RevB 09-20-10)
040505 DCX1 Emergency PLC Bypass Procedure (RevB 09-20-10)
040407 HVPS Door Gasket (RevB 5-07-09)
040402 IOX/DCX Maintenance Manual (RevC 10-12-05)
040321 IOX and DCX Motorized Breaker Retrofit (RevC 12-19-16)
040320 Fault Descriptors: IOX/DCX (RevA 2-23-05)
030631 IOX/DCX IPA Troubleshooting (RevA 11-8-04)
030630 VSWR Diagnostics w/Directional Couplers (RevA 11-10-04)
030618 LCD Screen Adjustment (RevA 4-11-05)
030617 Calibration of DCX System Power Meters (RevA2 11-15-10)
030616 Calibration of DCX HPA Power Meters (RevA 4-8-04)
030615 IOT Tuning w/Tracking Generator or Network Analyzer (RevC1 4-27-05)
030614 IOX/DCX HV Troubleshooting w/Hipotter (RevB2 2-13-04)
030612 IOX/DCX Focus Meters Cal Procedure (RevB 3-22-04)
030611 IOX/DCX Beam Meters Cal Procedure (RevB 3-22-04)
030610 IOX/DCX Body Current Meter Cal Procedure (RevA 8-17-03)
030609 IOX/DCX Ion Meters Cal Procedure (RevB 3-22-04)
030608 IOX/DCX Grid Meters Cal Procedure (RevC 9-18-07)
030606 IOX/DCX Interlock Check Procedure (RevB 2-25-05)
030605 Crowbar Filament Voltage (RevC 9-29-15)
030525 IOX/DCX Bias Adjust Procedure (RevB 3-22-04)
030524 IOX/DCX Filament Adjust Procedure (RevE 8-05-04)
030514 HVPS Resistor Board
030331 Stackpole Resistor (RevB 6-3-04)
030328 IOX/DCX Troubleshooting Table (RevH 1-10-07)
030324 Comark Customer Service Support Guide (RevI 12-05-12)
030224 Screw Terminals
020906 DCX Blower Replacement (RevC 1-16-12)
020710 IOX/DCX Thermistor Modification (RevA 2-23-05)
020709 Crowbar Retrofits & Procedure (RevC 4-09-09)
010904 DCX Power Monitor Modification (RevD 9-5-01)
990611 (061199) Crowbar Testing (RevD 3-22-04)
940911 High Voltage Safety Guidelines (RevC 5-14-04)
46744354-194 Advanced Crowbar Troubleshooting (RevB 5-10-06)
46745438-521 DCX Web Server Configuration Procedure (RevB 9-28-01)
Cooling Service Bulletins
120717 Cooling System Preparation/Cleaning (RevC 10-9-12)
100318 IOX/DCX Flow Meter Upgrade Procedure (RevA 5-18-10)
090303 Pump Seal Replacement Instructions (RevA 3-03-09)
060122 Cooling Pump Motor Lubrication Procedure
030629 Cooling System Flush Procedure (RevB 8-9-04)
900720 Cooling System Flushing Notification (RevC 2-21-12)</a
Exciter Service Bulletins
210716 Precorrections Procedure for Comark EXACT-V2 High End TV Exciter
200527 Precorrections Procedure for Comark EXACT-V2 High End TV Exciter (REVB 05-04-21)
170212 MODAP and ADAPT-IV DTV Exciter Support
130812 AGC Installation Procedure for Paragon & DCX (RevA 8-24-13)
130522 ATSC8000 & ATSC5000 DTV Exciter: Factory Reset Command (RevA 5-22-13)
110427 DCX AGC Setup Procedure for ADAPT IV Exciters (RevB 4-25-12)
040307 Universal Module Replacement Table (RevB 11-16-04)
040129 ADAPT Exciter DAP & CUDC Alignment (RevA 2-24-05)
040126 Advanced ADAPT Correction Procedure (RevC 2-25-09)
040125 ADAPT Exciter AGC Setup (RevB3 8-26-05)
030639 AC Consumption: DCX1 Non-Millennium Exciter Cabinet (RevA 12-12-05)
030638 AC Consumption: DCX Millennium Exciter Cabinet (RevB 12-12-05)
030633 ADAPT Frequency Adjustment (RevB 11-13-08)
030635 ADAPT Frequency Chart (RevA 1-16-05)
030624 DCX AGC Procedure (RevD 07-13-12)
030424 SMPTE-310 Signal Check (RevB 6-3-04)
030413 Replacement UHF Preamplifier Cover (RevD3 11-08-05)
46745601-108 ADAPT IV ATSC Digital Exciter User's Guide (RevA 6-7-07)
Remote Control Pinout Listing
180402 End of Production and Support Notice for the following IOT transmitters
170622 WEBGUI / ThalesView / TxView Support
170622 WEBGUI / ThalesView / TxView Support
130502 Stackpole Resistors in DCX/IOX Transmitter HPAs
110611 DCX Focus Supply Current Sense Upgrade Procedure
070727 IOX / DCX Millennium Cabinet Interlock Diagram
070302 Time and Date Change Procedure: IOX/DCX
061129 IOX / DCX Beam Control & CB3 Motor Operator Schematic
041114 PLC Battery Replacement
041014 Weekly DCX / Advantage Transmitter Log
041012 Panel View Procedures: DCX Millennium and Paragon
040831 Troubleshooting Crowbar Events: IOX/DCX
040824 List of Recommended ATSC Test Equipment
040706 Spellman Ion Power Supply Replacement
040704 IOX/DCX HPA Controller Backplane Replacement
040529 Emergency Tube Bypass: IOX/DCX
040507 Millennium/Paragon Emergency PLC Bypass Procedure
040505 DCX1 Emergency PLC Bypass Procedure
040407 HVPS Door Gasket
040402 IOX-DCX Maintenance Manual
040321 IOX and DCX Motorized Breaker Retrofit
040320 Fault Descriptors: IOX/DCX
030631 IOX / DCX IPA Troubleshooting
030630 VSWR Diagnosis with Directional Couplers
030618 LCD Screen Adjustment: IOX/DCX
030617 Calibration of DCX System Power Meters
030616 Calibration of DCX HPA Power Meters
030615 IOT Tuning with Tracking Generator or Network Analyzer
030614 IOT High Voltage Troubleshooting with Hipot Test Set
030612 Calibration of IOX / DCX Focus Voltage and Current Meters
030611 Calibration of IOX / DCX Beam Voltage and Current Meters
030610 Calibration of IOX / DCX Body Current Meter
030609 Calibration of IOX / DCX Ion Voltage and Current Meters
030608 Calibration of IOX / DCX Grid Voltage and Current Meters
030606 IOX / DCX Interlock Check Procedure
030605 Adjustment of Crowbar Filament Voltage
030525 Adjustment of IOT Bias Voltage and Idle Current
030524 Adjustment of IOT Filaments
030514 HVPS Resistor Board
030331 Stack Pole Resistor Maintenance
030328 IOX / DCX Troubleshooting Table
030324 Comark Customer Service Support Guide
030224 Screw Terminal Connectors
020906 DCX Transmitter Blower Motor Replacement Procedure
020710 IOX/DCX Thermistor Modification
020709 Crowbar Retrofits and Procedure
010904 DCX Power Monitoring Upgrade
990611 Periodic Crowbar Testing IOX/DCX
940911 High Voltage Safety Guidelines
46744354-194 Advanced Crowbar Troubleshooting
46745438-521 DCX Web Server Configuration Procedure
210716 REV A – 16 July, 2021 Precorrections Procedure for Comark EXACT-V2 High End TV Exciter HTML5
200527 REV B – 4 May, 2021 1 Precorrections Procedure for Comark EXACT-V2 High End TV Exciter {Flash}
170212 REV A – 17 February, 2017 1 MODAP and ADAPT-IV DTV Exciter Support
130812 AGC Installation Procedure for Paragon and DCX Series Transmitters
130522 ATSC 8000 & ATSC 5000 DTV Exciters: Factory Reset Command
110427 DCX AGC Setup Procedure for ADAPT IV Exciters
040307 Universal Module Replacement Table
040129 ADAPT Exciter DAP & CUDC Alignment
040126 Advanced ADAPT Correction Procedure
040125 ADAPT Exciter AGC: DCX, DCX Paragon, and Advantage
030639 AC Consumption: DCX1 Exciter Cabinet
030638 AC Consumption: DCX Millennium Exciter Cabinet
030633 ADAPT Frequency Adjustment
030635 ADAPT Frequency Chart
030624 DCX AGC Setup Procedure for MODAP Exciters
030424 SMPTE-310 Lock Problems & Quality Checks
030413 Replacement UHF Preamplifier Cover
46745601-108 ADAPT IV ATSC Digital Exciter User’s Guide
CXIC Phase II Compact DCX Single Cabinet DCX with Built-in Exciter
DCX Millennium with PanelView TouchScreen System Controller
DCX Millennium/Paragon Controller I/O Reference
DCX Non-Millennium with LED & Push Button System Controller
PLC I/O Pinouts DCX Millennium
PLC I/O Pinouts IOX/DCX (Non-Millennium)